COA Verification

Analytical Testing

Lab Test Data and Fill Weight

What has been measured, by which laboratory, on what date, and against what label. Including where no test exists. This page is a record of testing, not a claim about it.

What a usable lab report has to contain

1
A named laboratory
Not “third-party tested.” The lab is named, so the report can be checked against the lab that issued it.
2
Measured content against label
How many milligrams the vial actually contained, next to what the label says. This is the number most reports leave out.
3
Identity, by method
Which analytical method established the compound is what the label says, stated rather than implied.
4
A lot number that matches the vial
A report certifies one lot. Without a lot number printed on both the report and the vial, it cannot be tied to the material in hand.

Why fill weight, and not purity

Purity is close to universal in this category. Reports across the market cluster near the top of the scale, which makes it a poor way to tell suppliers apart. Content weight does not cluster. Published third-party data across the wider market includes results at 44.8 percent under label and 35.4 percent under label, and one lot returning 13.07mg in one vial and 9.47mg in another from the same batch.

That is the measurement worth publishing, and it is the one almost nobody does.

Reports on file

Every laboratory report currently held for material in the Etched Research supply chain. Measured content is compared to the labeled amount. A blank means no report exists, not that a test was passed.

CompoundMeasured vs labelPurityLaboratoryDate
BPC-157 10mg10.58mg  /  +5.8%99.734%Janoshik AnalyticalApril 2026
BPC-157 10mg11.39mg  /  +13.9%99.155%Janoshik AnalyticalMay 2026
TB-500 10mg11.59mg / 11.48mg99.605% / 99.512%Janoshik AnalyticalNovember 2025
TB-500 10mg12.07mg  /  +20.7%99.234%Janoshik AnalyticalMay 2026
MOTS-c 10mg10.74mg / 10.96mg99.278% / 99.706%Janoshik AnalyticalNovember 2025
SS-31 10mg10.69mg / 10.61mg99.811% / 99.861%Janoshik AnalyticalNovember 2025
KPV 10mg10.47mg / 10.36mg99.689% / 99.582%Janoshik AnalyticalNovember 2025
GHK-Cu 100mg98.26mg / 102.54mg99.868% / 99.756%Janoshik AnalyticalNovember 2025
Retatrutide 10mg10.61mg / 10.37mg99.419% / 99.477%Janoshik AnalyticalOctober 2025
Retatrutide 30mg30.61mg / 29.11mg99.393% / 99.764%Janoshik AnalyticalOctober 2025
Retatrutide 30mg32.79mg  /  +9.3%99.777%Janoshik AnalyticalMay 2026
Tirzepatide 30mg29.55mg  /  -1.5%99.903%Janoshik AnalyticalMay 2026
NAD+ 500mg496.78mg  /  -0.6%not requestedJanoshik AnalyticalApril 2026
BPC-157 (in BPC-157 + TB-500 Blend 20mg)12.68mg  /  +26.8%not requestedJanoshik AnalyticalJune 2026
TB-500 (in BPC-157 + TB-500 Blend 20mg)11.42mg  /  +14.2%not requestedJanoshik AnalyticalJune 2026
BPC-157 (in a 10mg BPC-157 + TB-500 blend vial, not in the shop)6.24mg  /  +24.8%not requestedJanoshik AnalyticalJuly 2026
TB-500 (in a 10mg BPC-157 + TB-500 blend vial, not in the shop)6.18mg  /  +23.6%not requestedJanoshik AnalyticalJuly 2026
BPC-157 (in GLOW 70mg)11.69mg  /  +16.9%not requestedJanoshik AnalyticalAugust 2026
TB-500 (in GLOW 70mg)11.24mg  /  +12.4%not requestedJanoshik AnalyticalAugust 2026
GHK-Cu (in GLOW 70mg)56.76mg  /  see notenot requestedJanoshik AnalyticalAugust 2026
Tesamorelin 10mg10.38mg  /  +3.8%99.043%Janoshik AnalyticalNovember 2025
Semax 10mg12.55mg  /  +25.5%99.905%Janoshik AnalyticalMay 2026
Thymosin Alpha-1 10mg12.31mg  /  +23.1%99.901%Janoshik AnalyticalMay 2026
GHK-Cu 50mg53.02mg  /  see note99.875%Janoshik AnalyticalAugust 2026
Selank 10mg12.49mg  /  +24.9%99.955%Janoshik AnalyticalAugust 2026
PT-141 10mg10.68mg  /  +6.8%99.847%Janoshik AnalyticalAugust 2026
Epithalonno report on file———
Ipamorelinno report on file———
5-Amino-1MQno report on file———
ARA-290no report on file———
Cagrilintideno report on file———
IGF-1 LR3no report on file———
KLOWno report on file———
MOTS-c 40mgno report on file———

Compound names above link to their product pages. See the full catalog.

Four things this page is not

1
Not lot-matched
The reports above carry no lot number. They describe material tested on the date shown, not the specific vial in any given shipment.
2
Not commissioned by us
These were ordered and paid for by the supplier, not by Etched Research. Etched-commissioned testing has not been run yet.
3
Not complete
Some compounds carry no report yet. They are named on the table with no report on file, rather than left off it.
4
Not a purity program
Most reports above carry a purity figure. A few don’t, because purity wasn’t part of what was requested on those. Each number describes one dated sample, not a standard Etched Research holds the catalog to.

Notes on the data

  • BPC-157 10mg, TB-500 10mg and Retatrutide 30mg each carry more than one dated report, from the same lab on the same compound. Two dated results is a stronger signal than one, since it shows the same lab checking the same compound over time rather than a single point-in-time snapshot.
  • The GHK-Cu figure in GLOW is unresolved. The report shows 56.76mg of copper complex containing 50.02mg GHK. Whether the 50mg label refers to the complex or to GHK content changes the result from roughly +13.5% to roughly +0.04%. It is listed as unresolved rather than reported as either.
  • The GHK-Cu 50mg figure is unresolved the same way. The report shows 53.02mg of copper complex containing 44.77mg GHK. Against the 50mg label that is roughly +6.0% if the label refers to the complex, and roughly -10.5% if it refers to GHK content.
  • GHK-Cu 50mg, Selank and PT-141 were tested in August 2026 on material submitted by current suppliers. The GHK-Cu report names a supplier batch that has not yet been matched to a lot Etched holds. The Selank and PT-141 reports name no batch.
  • Purity was not requested on three of the original four supplier-blend reports (the BPC-157 + TB-500 blend and GLOW rows above). One states it directly in its scope: identity and amount, purity not included. That is a gap in what was ordered, not a failed test.
  • Report documents are not posted. Each one names its manufacturer on the face of the page. Etched Research does not publish supplier identity, so the measurements are reproduced here rather than the documents.

What happens next

Lot identifiers will be assigned to inventory on arrival. Material from those lots will then be submitted for independent analysis, and the results will post to this page against the lot number, so a report can be matched to a vial. Laboratories under evaluation for that work include Janoshik Analytical and Freedom Diagnostics, selected against the four criteria at the top of this page rather than by name.

Until a lot has been tested under Etched Research, this page shows what the supply chain has measured and nothing further.

For research use only. Not for human consumption. Nothing on this page is a claim about any compound’s effect, safety, or suitability for any purpose.